ICM Controls ICM325A Single Phase Head Pressure Control

$74.95

ICM Controls ICM325A Single Phase Head Pressure Control

FREE SHIPPING ON ORDERS OVER $50

Description

ICM Controls ICM325A Low Ambient Head Pressure Control Air conditioning and refrigeration systems are commonly necessary to operate during cold temperatures. Server rooms, grocery stores and event spaces to name a few. When exposed to low ambient conditions, ACs and Heat Pumps condensing head pressure drops. If the head pressure gets too low, the system will not have enough pressure to operate properly and serious damage can occur including: Evaporator freeze-ups Hydraulic lock-ups Liquid slugging Compressor burnout Fan cycling and more The solution is to install an ICM Head Pressure Control. The ICM325A low ambient head pressure control ensures the condenser fan runs at an optimal speed for maximum efficiency. If the system pressure gets too low or the condenser temperature gets too cold, the ICM325A lowers the fan speed accordingly. Other head pressure controls on the market just turn the fan off completely. This method results in inconsistent head pressure, inconsistent cooling, rattling pipes & ducts, system leaks, and ultimately a shortened life span of the condenser fan motor and compressor. SPECIFICATIONS Operates as temperature or pressure sensitive motor fan speed control Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions Integral heat pump bypass circuitry allows electronic bypass of speed control Eliminates overshoots common to on/off and pressure switch controls Near field communication (phone tap) using the ICM OMNI App Features: hard start, low temperature bypass, isolated 24 VAC supply Controls up to 3 refrigeration circuits RoHS compliant / lead free design Typical application: A/C and heat pumps Universal 120-600VAC line voltage and 24-240VAC control voltage INPUT Line input: 120-600 VAC Control: 24-240 VAC (Jumper enabled) 50/60 Hz 1.8 VA max. OUTPUT (Motor 2) Maximum: 10 amps Minimum: 100 mA Operating temperature -40°F to +176°F (-40°C to +75°C) Temperature sensors 10K ohms at 77°F (25°C) Heat pump reversing valve input 24-240 VAC (Heat active default / jumper enabled cool active option) Cross Reference ACT: CES0110063-00, CES0110063-01, CES0110063-02, CES0110063-02A, CES0130024-01, 150-83-6A HOFFMAN: 800, 800A, 800AA, 814-50, 816-10 RANCO: E31Series JOHNSON CONTROLS: P66AAB/P66AAD ICM Controls: All Single Phase Head Pressure Control Models; ICM325H, ICM325HNV, ICM326HN, ICM327HN, ICM333. Including all single phase legacy LAQS Series Head Pressure Controls. ICM325A Sell Sheet ICM325A Installation Guide

Reviews

There are no reviews yet.

Be the first to review “ICM Controls ICM325A Single Phase Head Pressure Control”

Order Processing: After your payment is authorized and verified, we will start processing your order and this process can take from 1 to 2 business days, so please be patient with us. If we are unable to process your order due to inaccurate or incomplete payment or incorrect address information, your order processing may be delayed.

Carrier: UPS/FedEx/USPS. Delivery Timescale: More than 90% of orders arrive in 10 business days after despatch.

FREE RETURNS on all orders!
The following conditions must be met:

1. Items must be returned within 30 days after the purchase date.
2. Items must be unworn, undamaged and in original packaging.

ICM Controls ICM325A Single Phase Head Pressure Control